| Sign In | Join Free | My xxjcy.com |
|
Description : Connector Adapter Kits RoHS
Mfr. Part # : 6344-BK
Model Number : 6344-BK
The SBE80 and SBO60 connectors build upon the capabilities of two-pole SB connectors, offering up to 80 Amps of primary power per pole and an IEC 60950 touch-safe housing. These connectors are designed to accommodate up to 8 auxiliary power/signal contacts, enabling intelligent power switching, CAN bus communication, and interlock loop circuitry. They are suitable for applications requiring high current handling and reliable auxiliary connections, with silver-plated contacts for enhanced electrical performance and durability up to 10,000 mating cycles.
| Specification | SBE80 | SBO60 | Details |
|---|---|---|---|
| Primary Power Current Rating (6 AWG) | 80 Amps | 70 Amps | UL rated currents up to 80 amps per pole. Based on 105C rated cable, APP tooling, and 25C ambient. |
| Powerpole Auxiliary Current Rating (12 AWG) | 20 Amps | 20 Amps | |
| 1x4 Auxiliary Current Rating (12 AWG) | 20 Amps | 20 Amps | Up to 4 auxiliary circuits, 200 Volts each. |
| PPMX Auxiliary Current Rating (20 AWG) | 7 Amps | 7 Amps | Up to 8 auxiliary circuits, 300 Volts per contact. |
| Primary Power Voltage Rating | 600V AC/DC (UL) / 1504V AC/DC (CSA) | 600V AC/DC (UL) / 1504V AC/DC (CSA) | |
| Powerpole Auxiliary Voltage Rating | 600V AC/DC (UL) / 1504V AC/DC (CSA) | 600V AC/DC (UL) / 1504V AC/DC (CSA) | |
| 1x4 Auxiliary Voltage Rating | 200V AC/DC | 200V AC/DC | |
| PPMX Auxiliary Voltage Rating | 300V AC/DC | 300V AC/DC | |
| Dielectric Withstanding Voltage (Primary Power) | 2,200 Volts AC | 2,200 Volts AC | |
| Avg. Mated Contact Resistance (Power Contacts) | 0.200 mOhms | 0.200 mOhms | Using 1 1/4 of #6 AWG wire. |
| Hot Plug Current Rating (Power) | 60A (250 cycles at 120V DC) | 60A (250 cycles at 120V DC) | |
| Hot Plug Current Rating (Powerpole Auxiliary) | 30A | 30A | |
| Hot Plug Current Rating (1x4 Auxiliary) | 5A | 5A | |
| Mating Cycles (Silver Plated Contacts) | 10,000 | 10,000 | |
| Operating Temperature | -4F to 221F (-20C to 105C) | -4F to 221F (-20C to 105C) | Limited by thermal properties of housing. |
| Power Contact Wire Size Range | AWG 16 to 6 (1.3 to 13.3 mm) | AWG 16 to 6 (1.3 to 13.3 mm) | |
| Auxiliary Contact Wire Size Range (Powerpole) | AWG 16 to 12 (1.3 to 3.3 mm) | AWG 16 to 12 (1.3 to 3.3 mm) | |
| Auxiliary Contact Wire Size Range (1x4) | AWG 24 to 10 (0.25 to 5.3 mm) | AWG 24 to 10 (0.25 to 5.3 mm) | |
| Auxiliary Contact Wire Size Range (PPMX) | AWG 24 to 20 (0.50 to 0.25 mm) | AWG 24 to 20 (0.50 to 0.25 mm) | |
| Dimensions (Mated Length - A) | 0.28 inches (7.11 mm) | 0.22 inches (5.59 mm) | For #4 AWG contacts. |
| Dimensions (Mated Length - B) | 0.35 inches (9.0 mm) | 0.29 inches (7.3 mm) | For #4 AWG contacts. |
| Housing Styles | X, O style | X, O style | Smallest size of SBE. |
| Color Coding | Yellow, Orange, Red, Gray | Yellow, Orange, White | Housings of the same Voltage Color Code can mate but is not recommended. |
| Ordering Information (Minimum Quantity) | Housings: 400 (Yellow, Red, Gray), 25 (Orange) | Housings: 25 (Yellow, Orange, White) | |
| Ordering Information (Minimum Quantity) | Contacts: 1,000 (Loose Piece) | Contacts: 100 (Loose Piece) |
|
|
Robust Anderson Power 6344-BK connector with multiple auxiliary contacts and touch safe housing design Images |